Filtered Search Results
![](/catalog/search/static/resources/images/icons/back_to_top_icon.png)
Merck Millex™ Syringe Filter, Hydrophilic PTFE, HPF, 0.20 μm
For removing particulates, reducing signal-to-noise ratios and maintaining flat baselines
Pore Size | 0.2 μm |
---|---|
Disposable | Single-use |
Height (Metric) | 2.1 cm |
Temperature (English) Operating | 113°F |
Material (Membrane) | PTFE |
Color | Natural |
Volume (Metric) | 100 mL |
Material | HDPE |
Diameter (Metric) Membrane | 2.5 cm |
For Use With (Application) | Clarifying of aqueous and organic solutions with high particulate levels |
Sterility | Non-sterile |
Filtration Area | 3.9 cm2 |
Includes | Two different media, one graduated glass fiber prefilter, one hydrophilic PTFE membrane filter |
Connectors | Female luer lok/male luer slip |
Type | Millex-HPF/LCR Filter Unit |
Diameter (Metric) | 2.5 cm |
Diameter (Metric) Filter | 2.5 cm |
Temperature (Metric) Operating | 45°C |
Height (English) | 0.82 in. |
Merck Millex Samplicity™ Filters, Hydrophilic PTFE
To be used with the Samplicity Filtration System. Powered by vacuum, the system takes minimal manual effort to filter 1 to 8 samples into standard HPLC vials in seconds, with higher recovery than syringe filters provide.
Pore Size | 0.2 μm |
---|---|
Disposable | Single-use |
Connectors | Easy loading funnel inlet, Outlet tip for smooth transfer to HPLC vials |
Type | Millex™ Samplicity™ Filter |
Description | Filter Code: LG |
For Use With (Equipment) | Samplicity G2 Filtration System |
Housing Material | High density polyethylene (HDPE) housing |
Material (Membrane) | Hydrophilic PTFE |
Volume (Metric) | 0.3 to 1.6 mL |
Diameter (Metric) Membrane | 25 mm |
For Use With (Application) | Sample preparation for HPLC |
Sterility | Non-sterile |
Merck Millex™ Syringe Filter, Hydrophilic PTFE, HPF, 0.45 μm
For removing particulates, reducing signal-to-noise ratios and maintaining flat baselines
Pore Size | 0.45 μm |
---|---|
Disposable | Single-use |
Height (Metric) | 2.1 cm |
Temperature (English) Operating | 113°F |
Material (Membrane) | PTFE |
Color | Natural |
Material | HDPE |
Diameter (Metric) Membrane | 2.5 cm |
For Use With (Application) | Clarifying of aqueous and organic solutions with high particulate levels, analytical sample prep |
Sterility | Non-sterile |
Filtration Area | 3.9 cm2 |
Includes | Two different media, one graduated glass fiber prefilter, one 0.45 μm membrane filter |
Connectors | Female luer lok/male luer slip |
Type | Millex-HPF/LCR Filter Unit |
Diameter (Metric) | 2.5 cm |
Diameter (Metric) Filter | 2.5 cm |
Filter Type | Hydrophilic LCR |
Temperature (Metric) Operating | 45°C |
Height (English) | 0.82 in. |
Merck Millex™ Nonsterile 33mm Syringe Filters
SureTRACE
Supporting your traceability needs through proactive availability of certificates and change notifications.
Learn More
![BIOPHARMA](/content/dam/fishersci/glyphs/sure_trace.png)
Supporting your traceability needs through proactive availability of certificates and change notifications.
Learn More
Remove particulates, reduce signal-to-noise ratios and maintain flat baselines. Millex™ Nonsterile 33mm Syringe Filters are constructed of polyethylene housing with Durapore™ membranes for preparing samples for analysis. Available in two pore sizes.
Pore Size | 0.45 μm |
---|---|
Disposable | Single-use |
Type | Syringe Filter |
Diameter (Metric) | 33 mm |
Housing Material | PP |
Material (Membrane) | Durapore PVDF |
Diameter (Metric) Filter | 33 mm |
Volume (Metric) | <100 mL |
Color Code | Yellow |
For Use With (Application) | Analytical sample prep |
Hold up Volume (After Air Purge) | ≤80 μL |
Sterility | Non-sterile |
Filtration Area | 4.5 cm2 |
Merck Millex™ Syringe Filter, Fluoropore™ PTFE, Hydrophobic, 0.45 μm
SureTRACE
Supporting your traceability needs through proactive availability of certificates and change notifications.
Learn More
![BIOPHARMA](/content/dam/fishersci/glyphs/sure_trace.png)
Supporting your traceability needs through proactive availability of certificates and change notifications.
Learn More
For removing particulates, reducing signal-to-noise ratios and maintaining flat baselines
Pore Size | 0.45 μm |
---|---|
Disposable | Single-use |
For Use With (Application) | Analytical sample prep |
Sterility | Non-sterile |
Merck Millex™ Syringe Filter, PES, 0.22 μm
SureTRACE
Supporting your traceability needs through proactive availability of certificates and change notifications.
Learn More
![BIOPHARMA](/content/dam/fishersci/glyphs/sure_trace.png)
Supporting your traceability needs through proactive availability of certificates and change notifications.
Learn More
For removing particulates, reducing signal-to-noise ratios and maintaining flat baselines
Pore Size | 0.22 μm |
---|---|
Disposable | Single-use |
Housing Material | PP |
For Use With (Application) | Analytical sample prep |
Sterility | Non-sterile |
Merck Millex™-FA Syringe Filter Unit, Hydrophobic PTFE, 1 μm
Protect vacuum sources and tank/bioreactor venting from contamination and moisture damage. Millex™ Filters: Inlet and Outlet for Latex Tubing are constructed of sturdy polypropylene with hydrophobic PTFE membranes.
Pore Size | 1.0 μm |
---|---|
Disposable | Single-use |
For Use With (Equipment) | Filtering vacuum sources and tank/bioreactor venting with analytical sample preparation |
Diameter (Metric) | 50 mm |
Inlet Style | Stepped hose barb with female Luer slip |
Housing Material | PTFE |
Material (Membrane) | PTFE |
Diameter (Metric) Filter | 5 cm |
Volume (Metric) | 4 L |
For Use With (Application) | Analytical sample prep |
Autoclavable | Autoclavable |
Sterility | Non-sterile |
Merck Millex™-FG Syringe Filter Unit, Hydrophobic PTFE, 0.2 μm
Features a hydrophobic Fluoropore™ (PTFE) membrane. Millex™-FG Syringe Filter, 0.20μm, Hydrophobic PTFE provides broad chemical compatibility and is ideal for filtering samples in organic solvents or to prevent back-streaming of atmospheric moisture in venting applications.
Pore Size | 0.2 μm |
---|---|
Disposable | Single-use |
Merck Millex™ Syringe Filter, Glass Fiber, 25mm dia.
25 mm diameter, Millex-AP glass fiber membrane, hydrophilic.
Merck Millex™ Nonsterile Syringe Filters with PE Housing - Mitex
For removing particulates, reducing signal-to-noise ratios and maintaining flat baselines
Merck Millex™-FH Vent Filters, Hydrophobic PTFE, 0.45 μm
Protect vacuum sources and tank/bioreactor venting from contamination and moisture damage. Millex™ Filters: Inlet and Outlet for Latex Tubing are constructed of sturdy polypropylene with hydrophobic PTFE membranes.
Pore Size | 0.45 μm |
---|---|
Disposable | Single-use |
Type | Vent Filter |
For Use With (Equipment) | Filtering vacuum sources and tank/bioreactor venting with analytical sample preparation |
Diameter (Metric) | 50 mm |
Inlet Style | Stepped hose barb with female Luer slip |
Housing Material | PTFE |
Material (Membrane) | PTFE |
Diameter (Metric) Filter | 5 cm |
For Use With (Application) | Analytical sample prep |
Autoclavable | Autoclavable |
Sterility | Non-sterile |
Merck Millex™ Syringe Filter, Nylon, HPF, 0.45 μm
For removing particulates, reducing signal-to-noise ratios and maintaining flat baselines
Pore Size | 0.45 μm |
---|---|
Disposable | Single-use |
Type | Syringe Filter |
Diameter (Metric) | 25 mm |
Housing Material | HDPE |
Color | Natural |
Diameter (Metric) Filter | 25 mm |
Volume (Metric) | 100 mL |
Material | Nylon with Graduated Glass Fiber Prefilter |
For Use With (Application) | Analytical sample prep |
Hold up Volume (After Air Purge) | 250 μL |
Sterility | Non-sterile |
Filtration Area | 3.9 cm2 |
Merck Millex™ Syringe Filter, Durapore™ (PVDF), 0.22 μm
SureTRACE
Supporting your traceability needs through proactive availability of certificates and change notifications.
Learn More
![BIOPHARMA](/content/dam/fishersci/glyphs/sure_trace.png)
Supporting your traceability needs through proactive availability of certificates and change notifications.
Learn More
For removing particulates, reducing signal-to-noise ratios and maintaining flat baselines
Pore Size | 0.22 μm |
---|---|
Disposable | Single-use |
Type | Syringe Filter |
Inlet Style | Female Luer-Lok™ |
For Use With (Application) | Analytical sample prep |
Sterility | Non-sterile |
Merck Millex™ Filters: Inlet, Female Luer-Lok; Outlet, Male Luer Slip
Protect vacuum sources from contamination and moisture damage
Pore Size | 0.2 μm |
---|---|
Disposable | Single-use |
For Use With (Equipment) | Protect vacuum Sources From Contamination and Moisture Damage; Sterilize Ambient Air Entering Fermenters; Filter Incubator Gas to Protect Against Contamination; Filter Nitrogen and Air used to Dry Liquid Samples |
Diameter (Metric) | 25 mm |
Housing Material | PTFE |
Material (Membrane) | PTFE |
Diameter (Metric) Filter | 2.5 cm |
Volume (Metric) | 100 mL |
Autoclavable | Autoclavable |
Merck Millex™ Syringe Filter, Hydrophilic PTFE, 0.45 μm
SureTRACE
Supporting your traceability needs through proactive availability of certificates and change notifications.
Learn More
![BIOPHARMA](/content/dam/fishersci/glyphs/sure_trace.png)
Supporting your traceability needs through proactive availability of certificates and change notifications.
Learn More
For removing particulates, reducing signal-to-noise ratios and maintaining flat baselines
Pore Size | 0.45 μm |
---|---|
Disposable | Single-use |
Temperature (Metric) Max | 45°C |
For Use With (Application) | Analytical sample prep |
Sterility | Non-sterile |