Extraction Thimbles
Extraction Thimbles
- (1)
- (2)
- (9)
- (18)
- (101)
- (8)
- (29)
- (1)
- (1)
- (1)
- (26)
- (5)
- (2)
- (10)
- (6)
- (1)
- (1)
- (7)
- (1)
- (1)
- (3)
- (2)
- (1)
- (1)
- (3)
- (1)
- (1)
- (4)
- (1)
- (17)
- (1)
- (1)
- (1)
- (32)
- (1)
- (11)
- (7)
- (2)
Filtered Search Results
Fisherbrand™ Grade 7 Cellulose Fiber and Cotton Linter Extraction Thimble
Suitable for all extractors systems.
Product Type | Extraction Thimble |
---|---|
For Use With (Equipment) | Suitable for all extractors systems |
Grade | 7 |
Material | High Purity Cellulose Fibers and Cotton Linters |
For Use With (Application) | Extraction of Sulfur in gaseous masses, determination of dust and tar in industrial air and gases |
Velp Scientifica™ Extraction Cup
Velp Scientifica™ Extraction Cup for use with SER 148 Series Solvent Extractors.
Cytiva Whatman™ Grade 603 Cellulose Extraction Thimbles
Range in size and length to ensure optimal fit.. Whatman™ Grade 603 Cellulose Extraction Thimbles are for use with extracting pesticides from environmental samples and fat analysis in the food industry
Description | 603 Standard Cellulose Extraction Thimbles made from high-quality cellulose available in a range of sizes. |
---|---|
Product Type | Extraction Thimble |
Max. Temperature (English) | 266°F |
Grade | 603 |
Material | Cellulose |
Max. Temperature (Metric) | 130°C |
For Use With (Application) | To analyze fats and extract organic compounds |
Cytiva Whatman™ Cellulose Soxhlet Extraction Thimbles, Single 1mm Wall
Manufactured from high-quality alpha cellulose cotton linter for high-performance use in automated Soxhlet extractor systems. Whatman™ Cellulose Soxhlet Extraction Thimbles are intended for applications including use in air and waste gas analysis.
Description | GE’s Whatman cellulose thimbles are manufactured from high-quality alpha cellulose cotton linter for high-performance use in automated Soxhlet extractor systems. Used in air and waste gas analysis. |
---|---|
Product Type | Extraction Thimble |
For Use With (Equipment) | Soxhlet extractor |
Material | Cellulose |
Max. Temperature (Metric) | 120°C |
For Use With (Application) | Air and waste gas analysis |
Cytiva Whatman™ Cellulose Extraction Thimbles
Ensures optimal fit with its wide range of sizes suitable for use in thimble holders and automated extraction apparatus. Whatman™ Cellulose Extraction Thimbles are constructed of high-quality cellulose for excellent mechanical strength and retention.
Description | 603 Standard Cellulose Extraction Thimbles made from high-quality cellulose available in a range of sizes. |
---|---|
Product Type | Extraction Thimble |
For Use With (Equipment) | For automated extraction apparatuses |
Max. Temperature (English) | 248°F |
Material | Cellulose |
Max. Temperature (Metric) | 130°C |
For Use With (Application) | For the analysis of fats or pesticides in foods and soil materials as well as in many other procedures that involve a solid-liquid extraction |
Cytiva Whatman™ Cellulose Soxhlet Extraction Thimbles, double 2mm wall
Manufactured from high-quality alpha cellulose cotton linter for high-performance use in automated Soxhlet extractor systems. Whatman™ Cellulose Soxhlet Extraction Thimbles are intended for applications including use in air and waste gas analysis.
Particle Retention | 6μm |
---|---|
Description | GE’s Whatman cellulose thimbles are manufactured from high-quality alpha cellulose cotton linter for high-performance use in automated Soxhlet extractor systems. Used in air and waste gas analysis. |
Product Type | Extraction Thimble |
For Use With (Equipment) | Soxhlet extractor |
Quantity | 25 Pk. |
Wall Thickness | 2 mm |
Material | Cellulose |
Max. Temperature (Metric) | 120°C |
For Use With (Application) | Air and waste gas analysis |
Pyrex™ Borosilicate Glass Thimble
Pyrex™ Borosilicate Glass Thimble is highly resistant to chemical attack.
Includes | Sintered Glass disc |
---|---|
Length (Metric) | 95 mm |
Product Type | Filter Thimble |
Grade | Porosity 1 |
Material | Borosilicate Glass |
For Use With (Application) | Useful for chemical applications where it is required to weigh the extracted material |
Cytiva Whatman™ High Purity Glass Microfiber Soxhlet Extraction Thimbles
Designed to fit most Soxhlet extraction units. Whatman™ High Purity Glass Microfiber Soxhlet Extraction Thimbles are made of 100% borosilicate glass microfiber. They are well-suited to pollution monitoring when analysis of hot and acidic gases is required.
Description | GE’s Whatman 100% borosilicate glass microfiber (HP-GF) thimbles are designed to fit most Soxhlet extraction units. They are well-suited to pollution monitoring when analysis of hot and acidic gases is required. |
---|---|
Product Type | Extraction Thimble |
For Use With (Equipment) | Soxhlet extraction units |
Max. Temperature (English) | 932°F |
Grade | HP-GF |
Material | Borosilicate Glass Fibers |
Max. Temperature (Metric) | 500°C |
For Use With (Application) | Smoke stack gas monitoring. Soxhlet extraction. Analyzing pesticide residues. Determining oil/fat content of foods. Analysis of oil and grease in solid wastes. |
Lenz Laborglasintrumente Extraction Thimbles Porosity 0
Made of high quality materials. Each manufacturing step is tested through an extensive quality management system, based on DIN ISO 9001/EN 29001.
Material | Borosilicate Glass (3.3) |
---|---|
Porosity | 0 |
Lenz Laborglasintrumente Extractor Thimbles for Solids
Made of high quality materials. Each manufacturing step is tested through an extensive quality management system, based on DIN ISO 9001/EN 29001.
Standard Taper Joint No | NS 45/40 |
---|---|
Material | Borosilicate Glass (3.3) |
Cytiva Whatman™ High-Purity Glass Thimbles
Use for pollution monitoring when analysis of hot and acidic gases is required. Whatman™ High-Purity Thimbles are designed to fit most Soxhlet extraction units and can be used with solvents that are incompatible with cellulose thimbles.
Cytiva Whatman™ Quartz Microfiber Extraction Thimbles for Emission Testing
Support accurate, reproducible emission testing by providing low extractable levels and temperature resistance up to 800°C. Whatman™ Quartz Microfiber Extraction Thimbles are tapered for stack sample loading. Applications include emission testing, smoke stack gas sampling, gravimetric calculations in gases, analysis of hot and acidic gases, trace element analysis, and analysis of pesticides and residues.
Cytiva Whatman™ Glass Microfiber Extraction Thimbles, Grade 603G, without binder
Use for analysis of hot and acidic gases, including emission control and smoke tack gas monitoring. Whatman™ Glass Extraction Thimbles are designed to fit most Soxhlet extraction units and can be used with solvents that are incompatible with cellulose thimbles.