UV-Vis Spectrophotometers
UV-Vis Spectrophotometers
- (1)
- (1)
- (5)
- (1)
- (2)
- (1)
- (2)
- (1)
- (1)
- (2)
- (1)
- (7)
- (6)
- (3)
- (2)
- (1)
- (1)
- (12)
- (17)
- (1)
- (2)
- (33)
- (2)
- (1)
- (2)
- (1)
- (1)
- (2)
- (60)
- (9)
- (2)
- (2)
- (1)
- (8)
- (1)
- (8)
- (9)
- (2)
- (2)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (4)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (13)
- (1)
- (1)
- (2)
- (1)
- (35)
- (3)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (6)
- (1)
- (3)
- (9)
- (3)
- (2)
- (1)
- (4)
- (20)
- (1)
- (2)
- (4)
- (1)
- (11)
- (2)
- (24)
- (2)
- (2)
- (3)
- (2)
- (16)
- (2)
- (14)
- (42)
- (3)
Filtered Search Results
Thermo Scientific™ Evolution™ One/One Plus UV-Vis Spectrophotometers
Thermo Scientific™ Evolution™ UV-Vis Spectrophotometers combine reliable and versatile hardware with easy-to-learn, easy-to-use Thermo Scientific™ Insight™ Pro Software. Together they will meet the diverse needs your organization requires from an analytical tool.
Biochrom Ultrospec™ 30 Cell Density Meter
Ultrospec™ 30 Cell Density Meter for measuring density of bacteria and yeast cells in suspension.
Implen™ NanoPhotometer™ N60 Micro-Volume UV-VIS Spectrophotometer
The Implen NanoPhotometer™ N60 UV/Vis spectrophotometer for NanoVolume applications. Quantify DNA, RNA, proteins and scan other samples within seconds.
Connections | 2x USB A, USB B, HDMI, Ethernet, WiFi |
---|---|
Processor | Linux based NPOS |
Spectral Bandwidth | <1.8 nm |
Languages | English, French, German, Spanish, Portuguese, Russian, Chinese, Japanese |
Absorbance Range | 0.02 to 330 A |
Pathlength | 0.67 and 0.07 mm |
For Use With (Application) | Nucleic Acids, Protein UV, Protein Assays, Kinetics, OD600, Wavelength, Wavescan, Standard Curve, Absorbance Ratio, Concentration, Custom |
Light Source | Xenon Flash |
Measurement Time | 2.5 to 4.0 sec |
Sample Volume (Metric) | 0.3 to 2 μL |
Detector Type | 3648-element CCD Array |
Dimensions (L x W x H) | 20 x 20 x 12 cm |
Wavelength Accuracy | ± 0.75 nm |
No. of Samples | 1 |
System Requirements | Windows 7, 8, 10 (32 & 64 bit); OS X, iOS; Android OS |
Voltage | 90/250 V |
Stray Light | < 0.5% @ 240 nm using NaI |
Absorbance Accuracy | < 1.75% at 0.7 A at 280 nm of the reading |
Wavelength Range | 200 to 900 nm |
Measurement Range | 1 to 16,500 ng/μL |
Display | 7 in. Glove Compatible Touchscreen, 1024 x 600 pixels |
Biochrom BioDrop μLITE+
The BioDrop μLITE+ microvolume sample port uses no moving parts. This means that the instrument provides excellent reproducibility without the need for expensive calibration, and no concern your results may stray over time.
Lovibond™ Colorimeter Tablet Reagent: DPD No. 1
Use with MC500, MD600, SC450, MD100 colorimeters, SP600 spectrophotometer, Pool Control 9, AquaPRO3 Pool and AquaPRO6 Pool photometers and Scuba IIElectronic Pool Tester
Implen™ OD600 DiluPhotometer™
A small, easy to use instrument for the determination of cell density and Bradford assays in wavelengths ranging from 590 to 610 nm.
Thermo Scientific™ GENESYS™ 30 Visible Spectrophotometer
Perform both basic and complex analyses with the Thermo Scientific™ GENESYS™ 30 Visible Spectrophotometer, an intuitive, reliable solution for education or in the lab.
Photometric Accuracy | ±0.002 A (0 to 0.3 A), 0.5% of ABS reading (0.301 A to 2.5 A) |
---|---|
Connections | USB-A, USB-B |
Scan Speed | Automatic – up to 1200 nm/min. |
Printer Included | Thermal printer accessory with 80 mm width paper |
Noise | ≤0.001A at 0A |
Languages | English, French, German, Spanish, Italian, Portuguese, Russian, Chinese, Japanese, Korean, Thai, Arabic |
Detector Type | Silicon Photodiode |
Compartments | Accessible from top, front or side Able to accommodate cells up to 100mm pathlength Available accessory for test-tubes up to 25mm diameter and 150mm height Removable, washable sample compartment liner with magnetic placement and hold-down |
Stray Light | <0.1%T at 340 nm and 400 nm Measured using glass cutoff filters or NaNO2 at 340 nm |
Optical Design | Single Beam |
Photometric Repeatability | ± 0.002 A Measured at 1.0 A at 546 nm |
Weight (Metric) | 7.5 kg |
Wavelength Data Interval | 1 nm |
Electrical Requirements | External AC to DC converter. Voltage and Frequency (Hz) selected automatically, 100/250 V, 50/60 Hz |
Warranty | 2 years standard with 1 year extension upon registration of the instrument with Thermo Fisher Scientific within 6 months of purchase |
Photometric Range | -3A to +3A |
Wavelength Repeatability | < ±1 nm |
Spectral Bandwidth | 5 nm |
Baseline Flatness | <0.003 A, 325 to 1000 nm, smoothed |
Photometric Display | -3A to +3A, 0 to 200 000 %T, 0 to 9 999 999 C |
Type | Visible Spectrophotometer |
Dimensions (L x W x H) | 35.5x 38.5x 19.5 cm |
Wavelength Accuracy | ±2 nm |
Lamp Life | 1000 hrs. |
Keypad | Tactile rubber 23 keys with numeric keypad |
Drift | <0.002 A/hr. (At 500 nm after 2 hr. warmup.) Typical <0.004 A/hr. after 1 hr. warmup |
Wavelength Range | 325 to 1100 nm |
Product Line | GENESYS 30 |
Display | 5 in. 32-bit Color Display, 800 x 480 pixels |
Thermo Scientific™ GENESYS™ 40/50 Vis/UV-Vis Spectrophotometers
For teaching labs or quality control experts who require ruggedness, ease-of-use and software capability in UV-Vis spectrophotometry.
Thermo Scientific™ GENESYS™ 140/150 Vis/UV-Vis Spectrophotometers
Get the most for your QA/QC or teaching lab with a rugged, network ready spectrophotometer designed for repetitive measurements and ease of use.
Lovibond™ LC 100 Hand-Held Imaging Spectrophotometer
Creates conformance reports in either PDF or Excel formats that can easily be shared with PC or compatible printer
Includes | Spectrophotometer, holder, sample cells, USB cord, carrying case |
---|---|
Measurement Time | 1.8 sec. |
Display | TFT |
Biochrom Biowave 3+
The Biowave 3+ offers all the capabilities of a research grade UV/Vis spectrophotometer. Expect exceptionally high resolution with the 3 nm bandwidth. The robust design and reasonable cost make it great for students.
Height (Metric) | 100 mm |
---|---|
Beam Center Height | 15 mm |
Shape | Round |
Depth (English) | 15.3 in. |
Width (English) | 10 in. |
Photometric Linearity | ±1.3% or ±0.008 A (Whichever is Greater at 546 nm) |
Noise | ±0.005 peak to peak ±0.002 RMS |
Monochromator | Flat Grating |
Photometric Range | -0.3 to 2.5 A, 0.3 to 199 %T |
Wavelength Repeatability | ±1 nm |
Spectral Bandwidth | 3 nm |
Languages | English, French, German, Spanish, Italian, Chinese, Japanese |
Light Source | Xenon Flash |
Width (Metric) | 260 mm |
Detector Type | Twin CMOS Array |
Wavelength Accuracy | ±2 nm |
Depth (Metric) | 390 mm |
Voltage | 100/115/220/230 V |
Stray Light | <0.5 %T 340 nm |
Weight (English) | 6.6 lb. |
Photometric Repeatability | ±0.002 A to 0.5 A (at 546 nm) |
Wavelength Range | 190 to 1100 nm |
Weight (Metric) | 3 kg |
Height (English) | 3.9 in. |
Display | Graphic LCD |
Jenway™ Visible Spectrophotometer
Provides a wavelength range of 320 to 1000nm and includes absorbance, %T and concentration modes. Jenway™ Visibile Spectrophotometer is a high quality, low cost unit supplied with mains lead, pack 100 disposable cuvettes, 10 x 10mm cell holder, interface cable and PC application software on CD-ROM.
Biochrom™ Ultrospec 7500 UV-Vis Spectrophotometer
The Ultrospec 7500 is a simple-to-use instrument with highly advanced performance functionality and a sophisticated GLP mode to ensure high quality, consistent and reliable results. Versatile and precise, this instrument is ideal for use in any manufacturing or production laboratory.
Jenway™ Genova Nano Micro-volume Spectrophotometer
Measures small sample volumes as low as 0.5μL with a high degree of accuracy, reproducibility and speed. Jenway™ Genova Nano Micro-volume Spectrophotometer is ideal for DNA, RNA and protein measurements and can detect DNA concentrations as low as 2ng/μL.
Biochrom Lightwave 3+
The Lightwave 3+ is a split beam UV/Vis spectrophotometer that combines ease of use with the flexibility of a 40 mm sample port. Expect exceptionally high resolution with the 3 nm bandwidth.
Shape | Round |
---|---|
Width (English) | 10 in. |
Photometric Linearity | ±1.3% or ±0.008 A (Whichever is Greater at 546 nm) |
Noise | ±0.005 peak to peak ±0.002 RMS |
Languages | English, French, German, Spanish, Italian, Chinese, Japanese |
Light Source | Xenon Flash |
Width (Metric) | 260 mm |
Detector Type | Twin CMOS Array |
Voltage | 120/240 V |
Stray Light | <0.5 %T 340 nm |
Photometric Repeatability | ±0.002 A to 0.5 A (at 546 nm) |
Weight (Metric) | 3 kg |
Height (English) | 3.9 in. |
Height (Metric) | 100 mm |
Beam Center Height | 15 mm |
Depth (English) | 15.3 in. |
Monochromator | Flat Grating |
Photometric Range | -0.3 to 2.5 A, 0.3 to 199 %T |
Wavelength Repeatability | ±1 nm |
Spectral Bandwidth | 3 nm |
Type | UV-Vis Spectrophotometer |
Wavelength Accuracy | ±2 nm |
Depth (Metric) | 390 mm |
Weight (English) | 6.6 lb. |
Wavelength Range | 190 to 1100 nm |
Product Line | Lightwave 3+ |
Display | Graphic LCD |