Manual Gas Tight Syringes
Manual Gas Tight Syringes
Gas tight syringes for manual injections on GC instruments; includes fixed-needle, removable-needle formats in various sizes, needle gauges, needle point styles, and terminations; includes zero dead-volume and headspace syringes.
- (18)
- (26)
- (53)
- (1)
- (1)
- (118)
- (30)
- (91)
- (5)
- (1)
- (3)
- (1)
- (1)
- (11)
- (4)
- (36)
- (1)
- (1)
- (2)
- (65)
- (15)
- (82)
- (48)
- (33)
- (85)
- (12)
- (63)
- (3)
- (1)
- (1)
- (4)
- (136)
- (4)
- (10)
- (1)
- (58)
- (27)
- (14)
- (11)
- (54)
- (10)
- (1)
- (12)
- (9)
- (22)
- (42)
- (5)
- (2)
- (3)
- (201)
- (12)
- (12)
- (2)
- (3)
- (9)
- (107)
- (282)
- (1)
- (1)
- (8)
- (1)
- (1)
- (1)
- (1)
- (1)
- (72)
- (8)
- (15)
- (240)
- (13)
- (1)
- (73)
- (10)
- (194)
- (5)
- (1)
- (17)
- (1)
- (13)
- (4)
- (1)
- (124)
- (148)
- (49)
- (1)
- (2)
- (13)
- (1)
- (10)
- (44)
- (13)
- (36)
- (1)
- (75)
- (1)
- (5)
- (20)
- (64)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (6)
- (4)
- (9)
- (2)
- (16)
- (11)
- (1)
- (2)
- (11)
- (6)
- (6)
- (1)
- (12)
- (2)
- (1)
- (1)
- (1)
- (19)
- (4)
- (1)
- (1)
- (1)
- (2)
- (1)
- (9)
- (3)
- (13)
Filtered Search Results
Thermo Scientific™ Fixed-Needle, Gas-Tight Syringes for GC Instruments
Choose Thermo Scientific™ Fixed-Needle, Gas-Tight Syringes for accurate, reproducible GC sample introduction using an affixed needle and a plunger that creates a tight seal.
Connection Type | Fixed |
---|
Thermo Scientific™ Luer-Tip, Gas-Tight Manual Syringes for GC Systems
Get a gas-tight syringe for manual injections. This syringe features a Luer-Tip connection and is available in a variety of sizes.
Thermo Scientific™ Manual, Fixed Needle, Gas Tight Syringes for GC Instruments
Choose Thermo Scientific™ Fixed-Needle, Gas-Tight Syringes for manual accurate, reproducible GC sample introduction using an affixed needle and a plunger that creates a tight seal.
Hamilton™ 1000 Series Gastight™ Syringes: Luer Lock Syringes, TLL Termination (No Flange)
Mid-volume GASTIGHT syringe ideal for dispensing volumes from 100 μL up to 100 mL.
Thermo Scientific™ Male Luer-LOK Priming Syringes
Thermo Scientific™ Male Luer-LOK Priming Syringes offer easy, accurate and reproducible manual injections.
Hamilton™ 1700 and 1000 Series Gastight™ SampleLock™ Syringes, 22s Gauge
Hamilton SampleLock syringes allow you to collect, store, transport and analyze liquid or gaseous samples without the danger of evaporative loss or environmental contamination.
Needle Point Number | 2 |
---|---|
Quantity | Ea. |
Min. Temperature (English) | 50°F |
Material | Borosilicate Glass (Barrel),PTFE (Tip),Stainless Steel (Plunger) |
Max. Temperature (Metric) | 115°C |
For Use With (Application) | To collect, store, transport and analyze liquid or gaseous samples without the danger of evaporative loss or environmental contamination |
Product Type | General Purpose Syringe |
Diameter (Metric) Outer | 7.75 mm |
Connection Type | Sample Lock, Removable |
Max. Temperature (English) | 239°F |
Diameter (English) Outer | 0.3 in. |
Needle Point Style | Sharp, Bevel, Curved, Non-coring |
Diameter (Metric) Outer Needle | 0.72 mm |
Length (English) Needle | 2 in. |
Autoclavable | Not Autoclavable |
Min. Temperature (Metric) | 10°C |
Needle Gauge | 22s G |
Diameter (English) Outer Needle | 0.02 in. |
Includes | Plunger protection, inert Kel-F male luer cone |
---|---|
Needle Point Number | No Needle Included |
Accuracy | ±1% |
Product Type | Gastight Syringe |
Max. Temperature (English) | 248°F |
Quantity | Ea. |
Material | Borosilicate Glass (Barrel),PTFE (Tip) |
Max. Temperature (Metric) | 120°C |
For Use With (Application) | Suitable for gases or liquids for maximum inertness |
Accuracy | ±1% |
---|---|
Product Type | Gastight Syringe |
Connection Type | Removable |
Quantity | Ea. |
Length (English) Needle | 1.96 in. |
For Use With (Application) | Suitable for gases or liquids for maximum inertness |
Hamilton™ 1700/1000 Series Gastight™ Instrument Syringes: TLLX Termination
Syringes are designed to fit into, or with, various different instruments such as the MICROLAB™ 500 and MICROLAB 1000
Includes | Instrument plunger stop |
---|---|
Needle Point Number | No Needle Included |
For Use With (Equipment) | Microlab 500 Instruments |
Product Type | Gastight Syringe |
Connection Type | Luer Lock |
Max. Temperature (English) | 239°F |
Quantity | Ea. |
Min. Temperature (English) | 50°F |
Material | Borosilicate Glass (Barrel),PTFE (Tip) |
Max. Temperature (Metric) | 115°C |
SGE™ Gas Tight Plunger Syringe with PTFE Luer Lock
Headspace syringes with a special Luer lock probe
Trajan™ Beckman/Altex, Rheodyne, SSI, Valco Valve Replacement Needle
Removable needle replacement for manual syringes. For use with Beckman/Altex, Rheodyne, SSI, and Valco Valves
SGE™ Guided Plunger Syringes
Extended barrel guides plunger during injection. SGE™ Guided Plunger Syringes are suitable for industrial environments.
Needle Point Style | Bevel |
---|---|
Quantity | Ea. |
Diameter (Metric) Outer Needle | 0.47 mm |
Needle Gauge | 26 G |
Diameter (English) Outer Needle | 0.018 in. |
Hamilton™ 1000 Series Luer Tip Cemented Needle Syringes
Ideal for dispensing volumes from 100μL up to 100mL.
Product Type | Gastight Syringe Needle |
---|---|
Connection Type | Luer Tip, Cemented |
Needle Point Style | Custom |
Quantity | 1/Pk. |
Autoclavable | Not Autoclavable |
Min. Temperature (Metric) | 10°C |
Needle Gauge | Custom |
Max. Pressure | 200 psig (13.8 bar) |
Includes | Plunger protection, needle glued into barrel with epoxy solvent-resistant glue |
---|---|
Accuracy | ±1% |
Product Type | Gastight Syringe |
Needle Point Style | Fixed Bevel |
For Use With (Application) | Suitable for gases or liquids for maximum inertness |
Hamilton™ 1700 and 1000 Series Gastight™ SampleLock™ Syringes, 22 Gauge
Hamilton SampleLock syringes allow you to collect, store, transport and analyze liquid or gaseous samples without the danger of evaporative loss or environmental contamination.
Needle Point Number | 2 |
---|---|
Quantity | Ea. |
Min. Temperature (English) | 50°F |
For Use With (Application) | To collect, store, transport and analyze liquid or gaseous samples without the danger of evaporative loss or environmental contamination |
Diameter (Metric) Inner Needle | 0.41 mm |
Product Type | General Purpose Syringe |
Connection Type | Sample Lock, Removable |
Needle Point Style | Sharp, Bevel, Curved, Non-coring |
Diameter (Metric) Outer Needle | 0.72 mm |
Length (English) Needle | 2 in. |
Autoclavable | Not Autoclavable |
Min. Temperature (Metric) | 10°C |
Needle Gauge | 22 G |
Diameter (English) Outer Needle | 0.02 in. |
Diameter (English) Inner Needle | 0.01 in. |