Thermo Scientific™ Orion™ AQ4500 Turbidimeter
Utilize dual LED light sources and drinking water/wastewater methods approved for U.S. EPA regulatory reporting offered by this turbidity meter.
Type | Turbidity Meter |
---|---|
Battery Life | 2500 Hours |
Description | Turbidimeter and Calibration Kit |
Display Type | LED |
EPA Approved Methods | 180.1 |
Automatic Range Selection | Yes |
ISO Accepted Methods | ISO 7027 |
Certifications/Compliance | US EPA approval for Drinking Water Reporting per 40 CFR Part 141, vol. 74, no. 147, Monday, August 3, 2009. Rules and regulations pg 38351-38356.EPA 180.1 and ISO 7032 |
Light Source | LED, Multiple |
Thermo Scientific™ Orion™ AQUAfast™ AQ4500 Turbidity Meter Accessories
Ensure your turbidity meter has the accessories it needs, including turbidity vials, primary turbidity standards, Formazin turbidity standards, and more.
Thermo Scientific™ Eutech TN-100 Turbidimeter Calibration Kit
Simple, display-prompted push-button calibration
Thermo Scientific™ Orion™ AQUAfast AQ3010 Turbidity Meter
Generate an accurate turbidity reading quickly with the Thermo Scientific™ Orion™ AQUAfast AQ3010 Turbidity Meter
Thermo Scientific™ Eutech TN-100 Handheld Infrared Turbidity Meter Kit
Waterproof, portable, infrared Turbidity meter wtih extended range up to 2000 NTU, 0.01 resolution
WTW™ Turb™ Series 355 Portable Turbidity Meters
These portable turbidity meters are ideal for spot analysis in the field.
Height (Metric) | 48 mm |
---|---|
Warranty | 2 Years |
Length (Metric) | 70 mm |
Response Time | 14 sec. |
For Use With (Application) | Used for spot analysis in the field - especially for all applications |
Battery Type | 4 Micro (AAA) Alkaline Manganese |
Includes | Carrying case, 3 calibration standards (0.02- 10-1000 NTU), 2 empty 25 x 45m, 15mL sample volume cuvettes, cleaning tissues and 4 x AAA batteries |
Sample Size | 15 mL |
Type | Portable Turbidity Meter |
Display Type | LCD |
IP Rating | IP67 |
Temperature (Metric) Operating | 0°C to 50°C |
Weight (Metric) | 1.22 kg |
Resolution | 0.01NTU from 1 to 9.99, 0.1 NTU from 10.0 to 99.9, 1 NTU from 100 to 1000 |
Lovibond™ Infrared Lab Turbidimeter
Designed for quick and easy turbidity measurement in the laboratory
Hach Lange™ Portable Turbidimeter
Portable Turbidimeter offers unsurpassed ease of use and accuracy in turbidity measurement.
Velp Scientifica™ TB1 Turbidimeter
Velp Scientifica™ TB1 Turbidimeter that measures the turbidity of aqueous samples simply and accurately.
WTW™ Turb™ Series 430 Portable Turbidity Meters
With an accuracy of 0.01 NTU or ±2% of the measured value; these portable turbidity meters are ideal for all applications including drinking water testing, environmental monitoring, laboratory reference measurements and process control.
Height (Metric) | 86 mm |
---|---|
Accuracy | 0.01 NTU or ±2% of the measured value |
Sample Size | 20 mL |
Warranty | 2 Years |
Length (Metric) | 117 mm |
Display Type | LCD |
IP Rating | IP67 |
Temperature (Metric) Operating | 0°C to 50°C |
For Use With (Application) | Used for all applications including drinking water testing, environmental monitoring, laboratory reference measurements and process control |
Battery Type | 4 x AA |
Weight (Metric) | 0.6 kg |
Resolution | 0.01 from 0.00 to 9.99, 0.1 from 10 to 99.90, 1 from 100 to 1100 |
WTW™ Pocket Turbidimeter Turb 430 T / Set
Three-point calibration automatically with user guidance and calibration and documentation
Lovibond™ ET 730 Portable Floc Tester
Flocculation Testers (also known as Jar Testers) are designed for a range of applications - such as testing the efficiency of flocculation or precipitation agents
Lovibond™ ET 740 and ET 750 - Laboratory Floc / Jar Tester
Flocculation Testers (also known as Jar Testers) are designed for a range of applications - such as testing the efficiency of flocculation or precipitation agents
Includes | Power supply with US, EU and UK adapter, instruction manual |
---|---|
Height (Metric) | 26.03 cm |
Electrical Requirements | 115/230 V 50/60 Hz |
Type | Laboratory Flocculation Tester |
Width (English) | 13.5 in. |
Display Type | Digital |
Voltage | 115/230 V |
Frequency | 50/60 Hz |
Key Functions | Timer |
For Use With (Application) | For a range of applications such as testing the efficiency of flocculation or precipitation agents |
Width (Metric) | 34.2 cm |
Height (English) | 10.25 in. |
Resolution | 1 Revolution |
Hanna Instruments™ ISO Compliant Portable Turbidity Meters
High accuracy benchtop turbidity meter used to determine the turbidity of water and wastewater with high precision in the field as well as in the laboratory.
Grant Instruments™ Grant Bio™ Densitometer
Measures turbidity of cell suspensions in a variety of life science applications. Grant Instruments™ Densitometer is designed and factory calibrated to measure turbidity in the range of 0.5 to 4.0 McFarland units (DEN-1) 0.0 to >7.5 McFarland units (DEN-1B) with a small standard deviation.
Height (Metric) | 75 mm |
---|---|
Electrical Requirements | Input AC 120/230V 50/60 Hz Output DC 12 V |
Sample Size | ≥2 |
Dimensions (L x W x H) | 115 x 165 x 75 mm |
Precision | ±3% |
Voltage | 12 V |
Temperature (Metric) Operating | 4°C to 40°C |
Light Source | LED |
Width (Metric) | 165 mm |
Weight (Metric) | 0.7 kg |