UV-Vis Spectrophotometers
UV-Vis Spectrophotometers
- (1)
- (6)
- (1)
- (2)
- (1)
- (2)
- (1)
- (1)
- (2)
- (1)
- (7)
- (6)
- (3)
- (2)
- (1)
- (1)
- (12)
- (17)
- (1)
- (2)
- (33)
- (2)
- (1)
- (2)
- (1)
- (1)
- (2)
- (60)
- (9)
- (2)
- (2)
- (1)
- (8)
- (1)
- (8)
- (9)
- (2)
- (2)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (4)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (13)
- (1)
- (1)
- (2)
- (1)
- (35)
- (3)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (6)
- (1)
- (3)
- (9)
- (3)
- (2)
- (1)
- (4)
- (20)
- (1)
- (2)
- (4)
- (1)
- (11)
- (2)
- (24)
- (2)
- (2)
- (3)
- (2)
- (16)
- (2)
- (14)
- (42)
- (3)
Filtered Search Results
Thermo Scientific™ Evolution™ One/One Plus UV-Vis Spectrophotometers
Thermo Scientific™ Evolution™ UV-Vis Spectrophotometers combine reliable and versatile hardware with easy-to-learn, easy-to-use Thermo Scientific™ Insight™ Pro Software. Together they will meet the diverse needs your organization requires from an analytical tool.
Biochrom Biowave 3+
The Biowave 3+ offers all the capabilities of a research grade UV/Vis spectrophotometer. Expect exceptionally high resolution with the 3 nm bandwidth. The robust design and reasonable cost make it great for students.
Height (Metric) | 100 mm |
---|---|
Beam Center Height | 15 mm |
Shape | Round |
Depth (English) | 15.3 in. |
Width (English) | 10 in. |
Photometric Linearity | ±1.3% or ±0.008 A (Whichever is Greater at 546 nm) |
Noise | ±0.005 peak to peak ±0.002 RMS |
Monochromator | Flat Grating |
Photometric Range | -0.3 to 2.5 A, 0.3 to 199 %T |
Wavelength Repeatability | ±1 nm |
Spectral Bandwidth | 3 nm |
Languages | English, French, German, Spanish, Italian, Chinese, Japanese |
Light Source | Xenon Flash |
Width (Metric) | 260 mm |
Detector Type | Twin CMOS Array |
Wavelength Accuracy | ±2 nm |
Depth (Metric) | 390 mm |
Voltage | 100/115/220/230 V |
Stray Light | <0.5 %T 340 nm |
Weight (English) | 6.6 lb. |
Photometric Repeatability | ±0.002 A to 0.5 A (at 546 nm) |
Wavelength Range | 190 to 1100 nm |
Weight (Metric) | 3 kg |
Height (English) | 3.9 in. |
Display | Graphic LCD |
Biochrom BioDrop Duo+
The BioDrop Duo+ is a Micro-Volume UV/Vis spectrophotometer with pre-programmed life science methods and general spectrophotometric capabilities. This 2-in-1 instrument will fulfill the needs of the most demanding laboratories.
Shape | Round |
---|---|
Wavelength Repeatability | ±1 nm |
Spectral Bandwidth | 5 nm |
Languages | English, French, German, Spanish, Italian, Chinese, Japanese |
Pathlength | 10 mm + 0.5 mm |
For Use With (Application) | General Spectrophotometry and Life Science Methodology |
Light Source | Xenon Flash |
Measurement Time | >4 Seconds |
Sample Volume (Metric) | Minimum 0.5 μL |
Type | Microvolume UV-Vis Spectrophotometer |
Dimensions (L x W x H) | 280 x 410 x 190 mm |
Wavelength Accuracy | ±2 nm |
Voltage | 120/240 V |
Stray Light | <0.5 %T at 220 nm NaI; <0.5 %T (at 340 nm NaNO2) |
Weight (English) | 7.9 lb. |
Photometric Repeatability | ±0.003 A (0 to 0.5 A); ±0.007 A (0.5 to 1.0 A) |
Interface | Touch Screen Display (Color), USB Port |
Wavelength Range | 190 to 1100 nm |
Weight (Metric) | 3.6 kg |
Product Line | BioDrop Duo+ |
Display | Color Touchscreen |
Jenway™ 72 Series UV/Visible Spectrophotometer
The first scanning spectrophotometers in the Jenway range to leverage diode array technology to produce exceptionally fast results.
Thermo Scientific™ GENESYS™ 40/50 Vis/UV-Vis Spectrophotometers
For teaching labs or quality control experts who require ruggedness, ease-of-use and software capability in UV-Vis spectrophotometry.
Biochrom Biowave 3
The Biowave 3 offers all the capabilities of a research grade spectrophotometer with a robust design and a reasonable cost make it great for students.
Shape | Round |
---|---|
Width (English) | 10 in. |
Photometric Linearity | ±1.3% or ±0.008 A (Whichever is Greater at 546 nm) |
Noise | ±0.005 peak to peak ±0.002 RMS |
Languages | English, French, German, Spanish, Italian, Chinese, Japanese |
For Use With (Application) | UV/Vis Spectrophotometry |
Light Source | Xenon Flash |
Width (Metric) | 260 mm |
Detector Type | Twin CMOS Array |
For Use With (Equipment) | Microvolume Cuvettes |
Voltage | 100/115/220/230 V |
Stray Light | >0.5 %T 340 nm |
Photometric Repeatability | ±0.002 A to 0.5 A (at 546 nm) |
Weight (Metric) | 3 kg |
Height (English) | 3.9 in. |
Height (Metric) | 100 mm |
Beam Center Height | 15 mm |
Depth (English) | 15.3 in. |
Monochromator | Flat Grating |
Photometric Range | -0.3 to 2.5 A, 0.3 to 199 %T |
Wavelength Repeatability | ±1 nm |
Spectral Bandwidth | 5 nm |
Type | UV-Vis Spectrophotometer |
Wavelength Accuracy | ±2 nm |
Depth (Metric) | 390 mm |
Weight (English) | 6.6 lb. |
Wavelength Range | 190 to 1100 nm |
Product Line | Biowave 3 |
Display | Graphic LCD |
Biochrom™ Ultrospec 7500 UV-Vis Spectrophotometer
The Ultrospec 7500 is a simple-to-use instrument with highly advanced performance functionality and a sophisticated GLP mode to ensure high quality, consistent and reliable results. Versatile and precise, this instrument is ideal for use in any manufacturing or production laboratory.
Cole-Parmer™ Jenway™ 76 Series UV/Visible Scanning Spectrophotometers with CPLive™ Connectivity
Get cloud-based secure storage of your results and protocols with Jenway 76 Series UV/Visible Scanning Spectrophotometers with CPLive Connectivity
Connections | 2 x USB-A, 1 x USB-B, Ethernet RJ45 |
---|---|
Photometric Range | 0 to 199.9 %T |
Wavelength Repeatability | ± 0.5 nm |
Spectral Bandwidth | 1.5 nm |
Absorbance Range | −0.3 to +2.5 A |
Concentration | -300 to 9999 |
Light Source | Xenon |
Includes | 10GB memory |
Detector Type | Silicon Photodiode |
Type | Scanning UV/Visible Spectrophotometer with CPLive™ Cloud Connectivity |
Dimensions (L x W x H) | 50 x 28 x 15.6 cm |
Wavelength Accuracy | ±2 nm |
Voltage | 100/240 V |
Stray Light | <0.5% at 340 nm and 220 nm |
Absorbance Accuracy | ±0.01 A at 1.000 Absorbance |
Certifications/Compliance | CE |
Optical Design | Split Beam |
Hertz | 50/60 Hz |
Wavelength Range | 198 to 1000 nm |
Display | Touchscreen |
Jenway™ Genova Plus Life Science Spectrophotmeter
Pre-programmed with all the most common methods for protein analysis including Bradford, Lowry, Biuret, BCA and Direct UV methods. Jenway™ Genova Plus Life Science Spectrophotmeter can also be used as a standard spectrophotometer with measurement modes for photometrics, concentration, multi-wavelength, spectrum scanning, quantitation, and kinetics.
Jenway™ 72 Series Genova Bio Spectrophotometer
The Genova Bio is a simple, low cost, easy to use UV/visible spectrophotometer; dedicated for life science applications. The fast, responsive colour touchscreen and pre-programmed methods for the measurement of nucleic acid concentration and purity, protein assays and cell density, makes this spectrophotometer the ideal addition to any laboratory.
Jenway™ 6305 UV/Visible Spectrophotometer
Suitable for applications that require measurements in the UV-visible range. Jenway™ 6305 UV/Visible Spectrophotometer includes multi-parameter displays, full interfacing capability, and versatile sampling accessories.
Thermo Scientific™ GENESYS™ 140/150 Vis/UV-Vis Spectrophotometers
Get the most for your QA/QC or teaching lab with a rugged, network ready spectrophotometer designed for repetitive measurements and ease of use.
Cole-Parmer™ Jenway™ 74 Series Visible and UV/Visible Scanning Spectrophotometers with CPLive™ Connectivity
Get cloud-based secure storage of your results and protocols with Jenway 74 Series Visible and UV/Visible Scanning Spectrophotometers with CPLive Connectivity
Connections | 2 x USB-A, 1 x USB-B, Ethernet RJ45 |
---|---|
Photometric Range | 0 to 199.9 %T |
Wavelength Repeatability | ± 0.5 nm |
Spectral Bandwidth | 5 nm |
Absorbance Range | -0.3 to +2.5 A |
Pathlength | 10 to 100 mm |
Concentration | -300 to 9999 |
Includes | 10GB memory |
Detector Type | Silicon Photodiode |
Type | Spectrophotometer |
Dimensions (L x W x H) | 50 x 28 x 15.6 cm |
Wavelength Accuracy | ± 2 nm |
Photometric Accuracy Including Standard Tolerance | ±1%T |
Voltage | 100/240 V |
Absorbance Accuracy | ±0.01 A at 1.000 A |
Certifications/Compliance | CE |
Optical Design | Single |
Hertz | 50/60 Hz |
Display | Touchscreen |
Thermo Scientific™ GENESYS™ 180 UV-Vis Spectrophotometer, EU power cable
Perform UV-Vis measurements with a double beam with a reference cell position with the Thermo Scientific GENESYS 180 UV-Vis spectrophotometer.