Filtered Search Results
Search results for "syncronis"
Thermo Scientific™ Syncronis™ C18 Columns
Use for hydrophobic interaction reversed-phase separations.
Pore Size | 100 Å |
---|---|
Carbon Load | 16% |
Stationary Phase | C18 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
pH | 2 to 9 |
Surface Area | 320 m²/g |
USP Type | L1 |
Thermo Scientific™ Syncronis™ C18 HPLC Columns
Robust separations with highly pure, high surface area silica that is double endcapped Syncronis C18 preparative HPLC columns with inertness toward basic compounds.
Pore Size | 100 Å |
---|---|
Particle Size | 5 μm |
Carbon Load | 16% |
Stationary Phase | C18 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Packing Material | Spherical, Fully Porous, Ultrapure Silica |
Column Type | Reversed Phase |
pH | 2 to 9 |
Surface Area | 320 m²/g |
USP Type | L1 |
Thermo Scientific™ Syncronis™ Phenyl HPLC Columns
Use this high-surface-area column for aromatic compound separations.
Pore Size | 100 Å |
---|---|
Carbon Load | 11% |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
pH | 2 to 8 |
Surface Area | 320 m²/g |
USP Type | L11 |
Thermo Scientific™ Syncronis™ Amino HPLC Columns
Maximize liquid chromatography reproducibility and laboratory productivity using Thermo Scientific™ Syncronis™ Amino LC Columns.
Pore Size | 100 Å |
---|---|
Carbon Load | 4% |
Stationary Phase | Amino (NH2) |
Temperature | 60°C |
Phase | Reversed Phase, Normal Phase, Ion Exchange, HILIC |
Endcapped | Yes |
Packing Material | Spherical, Fully Porous, Ultrapure Silica |
Column Type | Mixed Mode |
pH | 2 to 8 |
Surface Area | 320 m²/g |
Max. Pressure | 5800 psi (400 bar) |
USP Type | L8 |
Thermo Scientific™ Syncronis™ HILIC HPLC Columns
Maximize liquid chromatography reproducibility and laboratory productivity using Thermo Scientific™ Syncronis™ HILIC LC Columns.
Pore Size | 100 Å |
---|---|
Carbon Load | 5% |
Stationary Phase | Zwitterionic |
Temperature | 60°C |
Column Type | HILIC |
pH | 2 to 8 |
Surface Area | 320 m²/g |
Thermo Scientific™ Syncronis™ C8 HPLC Columns
Use this C8 column for hydrophobic interaction reversed-phase separations.
Pore Size | 100 Å |
---|---|
Carbon Load | 10% |
Stationary Phase | C8 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
pH | 2 to 8 |
Surface Area | 320 m²/g |
USP Type | L7 |
Thermo Scientific™ Syncronis™ Silica HPLC Columns
Maximize liquid chromatography reproducibility and laboratory productivity using Syncronis Silica LC Columns.
Pore Size | 100 Å |
---|---|
Stationary Phase | Silica |
Temperature | 60°C |
Phase | Normal Phase |
Column Type | Normal Phase |
pH | 2 to 8 |
Surface Area | 320 m²/g |
USP Type | L3 |
Thermo Scientific™ Syncronis™ PREP HILIC HPLC Columns
Get enhanced retention of polar and hydrophilic analytes with Syncronis HILIC preparative HPLC columns that are problematic using reversed phase columns.
Pore Size | 100 Å |
---|---|
Particle Size | 5 μm |
Carbon Load | 5% |
Stationary Phase | Zwitterionic |
Temperature | 60°C |
Phase | HILIC |
Endcapped | No |
Packing Material | Spherical, Fully Porous, Ultrapure Silica |
Column Type | HILIC |
pH | 2 to 8 |
Surface Area | 320 m²/g |
USP Type | None |
Thermo Scientific™ Syncronis™ aQ C18 Polar Endcapped HPLC Columns
Use for predictable HPLC separations of compounds in highly aqueous mobile phases.
Pore Size | 100 Å |
---|---|
Carbon Load | 19% |
Stationary Phase | C18 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Polar |
Column Type | Reversed Phase |
pH | 2 to 8 |
Surface Area | 320 m²/g |
USP Type | L1 |
Thermo Scientific™ Syncronis™ C18 Reversed Phase HPLC Column, 5 μm, 10 mm x 250 mm
Pore Size: 100 Å; Column Phase: Reversed Phase
Thermo Scientific™ Syncronis™ Amino (NH2) Mixed Mode HPLC Column, 1.7 μm, 2.1 mm x 30 mm
Column Format: Analytical Column; Carbon Load: 4%; Pore Size: 100 Å; Column Phase: Reversed Phase, Normal Phase, Ion Exchange, HILIC